Search results for "air particulate"
showing 5 items of 5 documents
Analysis of 7Be and 210Pb concentration and 7Be/210Pb activity ratio in ground level air in Palermo (Italy)
2019
A series of measurements of particulate samples collected on paper filters in Palermo (Italy) during 1995–2005 has been performed to detect 210Pb air activity concentration and, along with previous similar data on 7Be, to evaluate their activity ratio. Average values for the daily activity concentrations of 7Be and 210Pb are found to be 4.7 and 0.6 mBq/m3 , respectively, 9.8 being the average activity ratio. Data confirm a seasonal behavior for both radionuclides. A correlation between 7Be and 210Pb air activity concentrations seems to exist, despite their different origins. The time behaviors of both 7Be and 210Pb air concentrations and 7Be/ 210Pb activity ratio have been compared with som…
RADIONUCLIDE CONCENTRATIONS IN AIR PARTICULATE AT PALERMO (ITALY) FOLLOWING FUKUSHIMA ACCIDENT
2012
Following the Fukushima accident, a series of samplings were carried out with a daily frequency to detect the arrival of radioactive contamination in air at Palermo (Italy) and to follow its evolution during the time. Air particulate collection was performed by suction of atmospheric air through cellulose filter paper by means of a high-volume air sampler (∼15 000 m(3) d(-1)). Spectrometric analysis of the filters highlights the presence of (131)I, (134)Cs, (137)Cs and, only for a few samples, traces of (132)Te-(132)I and (136)Cs. Maximum airborne concentrations were 883 μBq m(-3) for (131)I (only particulate), 81 μBq m(-3) for (137)Cs and 70 μBq m(-3) for (134)Cs. From a dose to population…
An experimental approach to efficiency calibration for gamma-ray spectrometric analysis of large air particulate filters
2013
Abstract A full-energy-peak efficiency (FEPE) calibration procedure for gamma-ray spectrometric analysis of air particulate samples collected on large filters is described herein. The experimental results are obtained for an unconventional measurement geometry, termed a “packet-sample”. The sample is obtained from a large cellulose filter (45 cm×45 cm) used to collect air particulate samples that is resized to dimensions suitable for spectrometric measurements (6 cm×6 cm×0.7 cm). To determine the FEPEs, many standards were created, i.e., some filters containing a small amount of ThO 2 and others containing a known amount of KCl. Efficiency curves obtained through best fits to experimental d…
Fission Product Activity Measurements in Air Particulate Filters Collected after Fukushima Accident at Palermo, Italy
2012
In the framework of routine operation of AGN-201 COSTANZA Nuclear research reactor, measurements of radionuclide air concentration are periodically performed by filtering an high volume of air through paper filters and by using HPGe gamma-ray spectrometry. After Fukushima accident, a series of samplings was carried out with a daily frequency so to detect the possible arrival of air radioactive contamination and to follow its evolution. Particulate collection was performed by suction of atmospheric air through 45cm × 45cm Sofiltra-Poelman HYN-75 (Bleu type) cellulose filter paper using a high-volume air sampler located on the roof of our department 20 m above ground-level. The sampling time …
Measurement of 210Pb airborne activity concentration by gamma-ray spectrometry of air particulate samplings
2009
Lead-210 (half-life 22.3 y), is a natural radionuclide, being produced in the atmosphere through radon decay. Due to its affinity for particles, it is rapidly fixed by aerosols and, with its long half-life is the most important tracer of long range atmospheric aerosol transport and removal processes. Main measurement techniques adopted to evaluate 210Pb air activity concentration differ in analysis and sample preparation methods. Some of them involved complex chemical processes or decay product detection (for example 210Po), with a long decay time period between sampling and experimental measurement. The availability of an high-volume particulate sampler (about 900 m3 h-1) combined with a l…